Commercial UPS
MR33 Series 50-600kVA

The Kehua MR33 series modularized 3-Phase in, 3-Phase out UPS utilizes advanced 3 level inverter technology, a more reliable redundancy design from the entire system down to the components, and digital technology interconnection. It has the advantages of high efficiency, high power density, easy scaling, scaling on demand, and occupies only a small amount of floor area and provides safe, reliable, and clear environmentally friendly power to loads.

UPS 600kVA

Advanced Technology

● Online double conversion
● Battery cold start function
● Advanced power module sleep mode
● Dual system control card
● Self-load test function
● Redundant design
● Compatible with lithium battery

 Excellent Flexibility

● Allow 100% three phase unbalance load
● Intelligent battery management
● Parallel expansion up to 8 units
● Fault Trace Management (FTM)
● Programmable dry contacts
● Fault Trace Management (Black box)
● Bypass power source N+1

Green Power

● Efficiency up to 96%
● Intelligent fan speed control
● ECO mode and EPO function

Technical Specifications

MODEL MR33120 MR33200 MR33300 MR33400 MR33500 MR33600
Power Module
Capacity (kW) 30 50
INPUT
Rated Voltage (Vac) 380/400/415
Voltage Range (Vac) L:L 138~485
Input Frequency (Hz) 40~70
Bypass Voltage Range (Vac) -15% (-20%/-30% optional) ~ +15%(+10%/+20% optional)
Power Factor ≥0.99
THDi 3% (linear load)
Phase 3Φ4W+PE
Battery Voltage (Vdc) ±192 (±168~±276 settable) ±192 (±180~±276 settable) ±240 (±168~±276 settable)
Charging Current (A) N×10 Maximum (N: the number of power modules)
OUTPUT
Capacity (kVA) 120 200 300 400 500 600
Power Factor 1
Phase 3Φ4W+PE
Waveform Sine wave
Voltage (Vac) L-L: 380, 400, 415 ±1%
Frequency (Hz) 50/60 ±0.2% (battery mode)
Three Phase Difference ≤1 degree
THDv ≤1% (linear load, full load), ≤4% (nonlinear load, full load)
Static Bypass Transfer Time 0
Max. System Efficiency 97%
Parallel Mode Advanced no-master-slave parallel technology, N+1 redundancy
Overload Capacity 106-110% load for 60 mins, 111%-130% load for 10 mins, 131%-150% load for 1 min, 151%-200% load for 200ms
GENERAL
Working Temperature (°C) -5~40
Storage Temperature (°C) -40~70
Relative Humidity 0%~95%, no condensing
Battery Type Lead-acid batteries and lithium iron phosphate batteries
Communication Interface RS485, RS232, dry contact (SNMP optional)
Noise (dB) < 65 < 70
Dimension (W×D×H) (mm) 600×860×2000 1200×860×2000
Weight (kg) Cabinet 180 224 236 427
Bypass Module 17 19 25 31
Power Module 27 33


Icon - Elements Webflow Library - BRIX Templates
Commercial UPS
MR33 Series 600-1200kVA

KEHUA@MR series 3-in 3-out UPS, adopts advanced 3-level inverter technology and reliable redundancy design from components to the whole machine. It has the advantages of high efficiency, high power density, easy expansion, capacity expansion as required and small occupied area, and provides reliable, stable and pure green power for loads.

MR33 Series UPS

High Efficiency

● The efficiency of the whole machine is as high as 97%, which greatly saves energy consumption (UPS heat consumption and air conditioning energy consumption) and reduces operating costs.
● The output power factor is 1.0 by default, with the same equipment input cost, greater active output and higher cost performance, which meets the requirements of different application scenarios for high output power factor.
● When the quality of mains supply is high, the ECO mode can be used to supply power to the load, the efficiency of the whole machine is as high as 99%, and the energy saving benefit is remarkable

User-friendly Interface

● Innovative application of data intelligent acquisition technology enables check of all product data in the parallel system on the control panel of any product.
● Large-size color touch screen design and humanized operation
● Double key combination of on and off, double protection of soft and hard
● EPO button with protective cover for emergency shut-off, misoperation prevention design, safety double upgrade
● Man-machine interface is friendly, close to customers' habits, and the software is rich in functions, which is convenient for users to read information and operate.
● Support asset management of vulnerable devices and spare parts

Green Power

● The latest IGBT rectification technology is adopted to realize ultra- low input current harmonics, which eliminates the pollution to the power grid, reduces the cost of power factor compensation and harmonic control, and reduces the cable loss. It protects both the load and the power grid.
● The input power factor is greater than 0.99, which improves the utilization rate of electric energy, reduces the distribution loss at the front end of UPS and reduces the input cost of customers.

Technical Specifications

Model MR33400 MR33500 MR33600 MR33800 MR331000 MR331200 MR331250
100kW System Capacity (kVA/kW) 100~400 100-500 100-600 100-800 100-1000 100-1200 /
125kW System Capacity (kVA/kW) / 125-500 125-600 125-800 125-1000 / 125-1250
Input
Voltage Range (Vac) 138~485 (324~485 no derating, 138~323 linear derating)
Frequency Range (Hz) 40~70
Power Factor >0.99
Phase 3Ph+N+PE/3Ph+PE (optional)
Bypass Synchronization Tracking Range (Hz) 50/60 ±4
Bypass Input Voltage Range (Vac) 304~438
Battery Voltage (VDC) ±180~±300
Output
Power Factor 1.0
Phase 3Ph+N+PE
Voltage (Vac) 380/400/415 ±1%
Frequency (Hz) 50/60 ±0.1%
THDv THD<1% (linear load), THD<3% (nonlinear load)
Max. Efficiency 97%
Overload Capacity 106-110% load for 60 minutes, 111%-125% load for 10 minutes, 126%-150% load for 1 minute, 151%-200% load change to bypass immediately
Static Bypass Transfer Time 0
Cool Start Yes
Other
Battery Type Lead-acid batteries and lithium iron phosphate batteries
Battery Pack Sharing Function Yes
Communication Interface RS232, RS485, Dry contact, MODBUS, SNMP (optional)
Alarm Input abnormal, battery low-voltage, output overload, UPS failure
Protection Short-circuit, overload, over-temperature, battery under voltage, input under voltage
Noise (dB) <70
Operating Temperature (ºC) 0-40
Relative Humidity 0~95%, no condensation
Routing Mode Upper and lower incoming lines Upper incoming line
Dimension (W×D×H) (mm) 1200×1000×2000 1400×1000×2000 1800×1000×2000
Weight (kg) Cabinet 480 506 580 650 740
Bypass Module 32 50 60 80
100kW Module 55
125kW Module 60


Icon - Elements Webflow Library - BRIX Templates
Industrial UPS
FR-UK33 Series 10-600kVA

3 Phase Online Transformer-based UPS (10-600kVA)
The KEHUA FR-UK series medium/high power UPS uses the industry’s tried and tested phase-controlled rectification technology and power components and inverter module with excellent performance, as well as smart multi-mode battery management technology and a variety of power management software along with a reinforced combination cabinet structure to provide high quality and highly reliable uninterruptible sine wave power to loads and is cost effective and has a good user base.

FR-UK33 Series UPS

Advanced Technology

● Online double conversion
● Battery cold start function
● Advanced power module sleep mode
● Online double conversion
● Wide input voltage range
● IGBT inverter and output isolation transformer
● Advanced battery charging management
● Advanced no-master-slave parallel technology (optional)
● Dual system control card
● Self-load test function
● Redundant design
● Compatible with lithium battery

 Excellent Flexibility

● Allow 100% three phase unbalance loads
● Intelligent RS232/RS485 & DB9 dry contact communication port
● DC cold start function (optional)
● Intelligent battery monitor system-MMBM (optional)
● MODBUS & SNMP adapter (optional)

Green Power

● High reliability DSP control
● Intelligent fan speed control
● Full protection function
● ECO mode and EPO function
● Efficiency 98% at ECO-mode
● 10,000 events logs
● Battery self-test function
● 12 Pulse rectifier (optional)
● Bypass isolation transformer (optional)

Technical Specifications

Responsive Table Example
MODEL FR-UK 3310 FR-UK 3320 FR-UK 3330 FR-UK 3340 FR-UK 3360 FR-UK 3380 FR-UK 33100 FR-UK 33120 FR-UK 33160 FR-UK 33200 FR-UK 33250 FR-UK 33300 FR-UK 33400 FR-UK 33500-12P FR-UK 33600-1
Voltage (Vac) 10 20 30 40 60 80 100 120 160 200 250 300 400 500 600
INPUT
Voltage (Vac) L-L: 285-475 (323-475 at full load)
Frequency (Hz) 40-70
Power Factor ≥0.99
Phase 3W+N+PE
BYPASS
Voltage (Vac) ±10%/±15%/±20% (default ±20%)
Frequency (Hz) ±5%/±10% (default ±10%)
Overload 130%: long run, 170%: 10 min, 200%: 1 min, above 170%: 200ms
OUTPUT
Voltage (Vac) L-L: 380/400/415 ±1%
Frequency (Hz) 50/60 ±0.1% (battery mode)
Power Factor 0.9
THDv ≤2% (resistive full load)
AC/AC Efficiency (Max.) 94%
Overload 124%: long run, 125%: 10 min, 150%: 1 min, 170%: 200ms
Transfer Time (ms) 0 (Mains mode-Battery mode), ≤1 (Inverter mode-Bypass mode)
Crest Factor 3:1
BATTERY
Battery Type Lead-acid/S³ Lithium-ion batteries
Voltage (Vdc) 348 (360 settable) 384 (348/360/372 settable)
Charging Current (A) 10~40 10-100
GENERAL
Communication RS485, Dry contact, Optional: SNMP card
Display 7" touch screen
Noise (dB) <65 <70
Working Temperature (°C) -5~40
Altitude (m) 2000
Relative Humidity 0 ~ 95%, no condensation
Protection Grade IP20
Agency/ Certification/ Conformance EN IEC 62040-1, EN IEC 62040-2, EN IEC 62040-3
Icon - Elements Webflow Library - BRIX Templates
Industrial UPS
KR33 Series 300-1200kVA

·  Computer room
·  Data center
·  Precision instrument
·  Commercial facility
·  Intelligent equipment
·  Telecom system
·  Industry

KR33 Series 300 UPS

Advanced Technology

● Three level inverter technology
● Support parallel mode up to 9.6MVA
● External input/output transformer connection

Flexible Design

● Common battery bank sharing in parallel system
● Multiple communication interface
● 3-stage battery charging mode
● Self-load test function without load enables onsite commission
● Common bypass cabinet
● External input and output isolation transformer

Green Power

● High AC/AC efficiency up to 97%
● ECO mode efficiency up to 99%
● High power factor up to 1
● Low THDi ≤2%

Technical Specifications

UPS Models Comparison
MODEL KR33300 KR33400 KR33500 KR33600 KR33800 KR331000 KR331200
Capacity (kVA) 300 400 500 600 800 1000 1200
INPUT
Voltage (Vac) L-L: 228-475 (323-475 at full load)
Frequency (Hz) 40-70
Power Factor ≥0.99
THDi ≤3% (resistive full load)
Phase 3W+N+PE
BYPASS
Voltage (Vac) ±10%/±15%/±20% (default ±20%)
Frequency (Hz) ±5%/±10% (default ±10%)
Overload 124%: long run, 150%:10min, 170%: 1min, above 170% 10s
OUTPUT
Voltage (Vac) L-L: 380/400/415±1%
Frequency (Hz) 50/60±0.1 (battery mode)
Power Factor 1.0
THDv ≤1% (resistive full load)
AC/AC Efficiency (Max.) 97%
Overload 105%: long run, 110%: 60min, 125%: 10min, 150%: 1min, above 150% 1s
Transfer Time (ms) 0 (Mains mode-Battery mode), ≤1 (Inverter mode-Bypass mode)
Crest Factor 3:1
BATTERY
Battery Type Lead-acid/ S3 Lithium-ion batteries
Voltage (Vdc) 480 (384-528, 456-528 at full load) 528 (384-528, 480-576 at full load)
Charging Current (A) 25-100 25-200
GENERAL
Communication RS232/RS485, Dry contact Optional: SNMP card
Display 7" touch screen
Noise (dB) <65
Working Temperature (°C) -5~40
Altitude (m) 2000
Relative Humidity 0 ~ 95%, no condensation
Protection Grade IP20
Agency/Certification/Conformance EN IEC 62040-1, EN IEC 62040-2
Dimension (W×D×H) (mm) 1000×900×1950 1400×900×1950 1900×900×1950 3000×900×1950
Weight (kg) 750 1100 1450 2400